~ Concerns regarding use of steel piles in corrosive areas.
~ Concrete piles are preferred in corrosive areas, but subsurface conditions control pile type.
~ Steel piles allow flexibility in length for required bearing, but require galvanizing or metallization.
~ Piles required repairs to galvanizing in numerous small areas.
~ There was a suggestion to use concrete piles and take advantage of set on future projects in corrosive areas.